189 lines
7.5 KiB
TOML
189 lines
7.5 KiB
TOML
|
|
||
|
#Settings for the crafter
|
||
|
[crafter]
|
||
|
#Amount of RF used per crafting operation
|
||
|
#Range: > 0
|
||
|
rfPerOperation = 100
|
||
|
#How many operations to do at once in fast mode
|
||
|
#Range: > 0
|
||
|
speedOperations = 5
|
||
|
#Maximum RF storage that the crafter can hold
|
||
|
#Range: > 0
|
||
|
crafterMaxRF = 50000
|
||
|
#RF per tick that the crafter can receive
|
||
|
#Range: > 0
|
||
|
crafterRFPerTick = 500
|
||
|
|
||
|
#Settings for the screen system
|
||
|
[screen]
|
||
|
#Maximum RF storage that the screen controller can hold
|
||
|
#Range: > 0
|
||
|
screenControllerMaxRF = 60000
|
||
|
#RF per tick that the the screen controller can receive
|
||
|
#Range: > 0
|
||
|
screenControllerRFPerTick = 1000
|
||
|
#RF per tick/per block for the button module
|
||
|
#Range: > 0
|
||
|
buttonRFPerTick = 9
|
||
|
#RF per tick/per block for the elevator button module
|
||
|
#Range: > 0
|
||
|
elevatorButtonRFPerTick = 0
|
||
|
#RF per tick/per block for the clock module
|
||
|
#Range: > 0
|
||
|
clockRFPerTick = 1
|
||
|
#RF per tick/per block for the computer module
|
||
|
#Range: > 0
|
||
|
computerRFPerTick = 4
|
||
|
#RF per tick/per block for the counter plus module
|
||
|
#Range: > 0
|
||
|
counterPlusRFPerTick = 30
|
||
|
#RF per tick/per block for the counter module
|
||
|
#Range: > 0
|
||
|
counterRFPerTick = 4
|
||
|
#RF per tick/per block for the dimension module
|
||
|
#Range: > 0
|
||
|
dimensionRFPerTick = 6
|
||
|
#RF per tick/per block for the energy module
|
||
|
#Range: > 0
|
||
|
energyRFPerTick = 4
|
||
|
#RF per tick/per block for the energy plus module
|
||
|
#Range: > 0
|
||
|
energyPlusRFPerTick = 30
|
||
|
#RF per tick/per block for the fluid module
|
||
|
#Range: > 0
|
||
|
fluidRFPerTick = 4
|
||
|
#RF per tick/per block for the fluid plus module
|
||
|
#Range: > 0
|
||
|
fluidPlusRFPerTick = 30
|
||
|
#RF per tick/per block for the itemstack plus module
|
||
|
#Range: > 0
|
||
|
itemstackPlusRFPerTick = 30
|
||
|
#RF per tick/per block for the itemstack module
|
||
|
#Range: > 0
|
||
|
itemstackRFPerTick = 4
|
||
|
#RF per tick/per block for the machine information module
|
||
|
#Range: > 0
|
||
|
machineInfoRFPerTick = 4
|
||
|
#RF per tick/per block for the redstone module
|
||
|
#Range: > 0
|
||
|
redstoneRFPerTick = 4
|
||
|
#RF per tick/per block for the text module
|
||
|
#Range: > 0
|
||
|
textRFPerTick = 0
|
||
|
#How many times the screen will update. Higher numbers make the screens less accurate but better for network bandwidth
|
||
|
#Range: > 0
|
||
|
screenRefreshTiming = 500
|
||
|
|
||
|
#Settings for the spawner system
|
||
|
[spawner]
|
||
|
#Maximum amount of injections we need to do a full mob extraction.
|
||
|
#Range: > 1
|
||
|
maxMobInjections = 10
|
||
|
|
||
|
#Settings for the tank
|
||
|
[tank]
|
||
|
#Maximum tank capacity (in mb)
|
||
|
#Range: > 0
|
||
|
maxCapacity = 32000
|
||
|
|
||
|
#Settings for the teleportation system
|
||
|
[teleporter]
|
||
|
#Maximum RF storage that the matter transmitter can hold. This should be at least equal to 'rfStartTeleportDim'
|
||
|
#Range: > 0
|
||
|
transmitterMaxRF = 200000
|
||
|
#RF per tick that the matter transmitter can receive. It is recommended to keep this at least equal to 'rfTeleportPerTick'
|
||
|
#Range: > 0
|
||
|
transmitterRFPerTick = 1000
|
||
|
#Maximum RF storage that the matter receiver can hold
|
||
|
#Range: > 0
|
||
|
receiverMaxRF = 100000
|
||
|
#RF per tick that the matter receiver can receive
|
||
|
#Range: > 0
|
||
|
receiverRFPerTick = 500
|
||
|
#Maximum RF storage that the dialing device can hold
|
||
|
#Range: > 0
|
||
|
dialerMaxRF = 50000
|
||
|
#RF per tick that the dialing device can receive
|
||
|
#Range: > 0
|
||
|
dialerRFPerTick = 100
|
||
|
#Maximum RF storage that the advanced charged porter item can hold (note that teleporting this way uses 50% more RF then with a matter transmitter)
|
||
|
#Range: > 0
|
||
|
advancedChargedPorterMaxRF = 1000000
|
||
|
#Maximum RF storage that the charged porter item can hold (note that teleporting this way uses 50% more RF then with a matter transmitter)
|
||
|
#Range: > 0
|
||
|
chargedPorterMaxRF = 200000
|
||
|
#RF per tick that the the charged porter item can receive
|
||
|
#Range: > 0
|
||
|
chargedPorterRFPerTick = 2000
|
||
|
#The speed bonus for the advanced charged porter (compared to the normal one)
|
||
|
#Range: > 0
|
||
|
advancedSpeedBonus = 4
|
||
|
#The horizontal range the dialing device uses to check for transmitters. These are the transmitters the dialing device will be able to control
|
||
|
#Range: > 0
|
||
|
horizontalDialerRange = 10
|
||
|
#The vertical range the dialing device uses to check for transmitters
|
||
|
#Range: > 0
|
||
|
verticalDialerRange = 5
|
||
|
#The amount of RF consumed when dialing a transmitter to another receiver
|
||
|
#Range: > 0
|
||
|
rfPerDial = 1000
|
||
|
#The amount of RF consumed when the dialing device checks for the capabilities of a receiver ('Check' button)
|
||
|
#Range: > 0
|
||
|
rfPerCheck = 5000
|
||
|
#The amount of RF that is consumed by the matter transmitter when a dial is active
|
||
|
#Range: > 0
|
||
|
rfDialedConnectionPerTick = 10
|
||
|
#The amount of RF that is consumed by a matter transmitter when the player goes to stand in the teleportation beam allowing the teleportation process to start. This value is used for a teleport in the same dimension. In addition to this value the 'rfStartTeleportDist' is also added per traveled distance
|
||
|
#Range: > 0
|
||
|
rfStartTeleportLocal = 5000
|
||
|
#The amount of RF that is consumed by a matter transmitter when the player goes to stand in the teleportation beam allowing the teleportation process to start. This version is for a teleportation to another dimension and in this case 'rfStartTeleportDist' is not used. This value also acts as the maximum rf that can be consumed for a local teleport
|
||
|
#Range: > 0
|
||
|
rfStartTeleportDim = 100000
|
||
|
#For every unit in distance this value is added to the initial RF cost for starting the teleportation. This value is not used when teleporting to another dimension
|
||
|
#Range: > 0
|
||
|
rfStartTeleportDist = 10
|
||
|
#For the duration of the teleport process this value represents the amount of RF that is consumed by the matter transmitter for every tick
|
||
|
#Range: > 0
|
||
|
rfTeleportPerTick = 500
|
||
|
#The amount of RF/tick an idle dialed transmitter consumes
|
||
|
#Range: > 0
|
||
|
rfMatterIdleTick = 0
|
||
|
#This is the amount of RF that is consumed at the receiving side for every teleport. This RF is only consumed when the teleportation actually happens
|
||
|
#Range: > 0
|
||
|
rfPerTeleportReceiver = 5000
|
||
|
#This is the amount of RF that is consumed at a boosted transmitter in case the receiver doesn't have enough power
|
||
|
#Range: > 0
|
||
|
rfBoostedTeleport = 20000
|
||
|
#The base time used for a teleportation for a local teleport. The 'timeTeleportDist' value is added per distance traveled
|
||
|
#Range: > 0
|
||
|
timeTeleportBaseLocal = 5
|
||
|
#The base time used for a teleportation to another dimension. The 'timeTeleportDist' value is not used
|
||
|
#Range: > 0
|
||
|
timeTeleportBaseDim = 50
|
||
|
#The amount of time that is added depending on distance for a local teleport. This value is in militicks which means that 1000 is one tick and one tick is 1/20 of a second
|
||
|
#Range: > 0
|
||
|
timeTeleportDist = 10
|
||
|
#Set this to false to disable the 'whoosh' message on teleport
|
||
|
whooshMessage = true
|
||
|
#The volume for the teleporting sound (1.0 is default)
|
||
|
#Range: 0.0 ~ 1.0
|
||
|
volumeTeleport = 1.0
|
||
|
#The volume for the error sound when teleportation fails (1.0 is default)
|
||
|
#Range: 0.0 ~ 1.0
|
||
|
volumeTeleportError = 1.0
|
||
|
#The amount of ticks that a matter transmitter with destination checker will wait before checking a receiver in case the chunk is not loaded (-1 to disable this check completely)
|
||
|
#Range: > -1
|
||
|
checkUnloadedChunk = -1
|
||
|
#The amount of ticks that a matter transmitter with destination checker will wait before checking a receiver in case the world is not loaded (-1 to disable this check completely)
|
||
|
#Range: > -1
|
||
|
checkUnloadedWorld = -1
|
||
|
#If this is true then all usages of the teleport system are logged
|
||
|
logTeleportUsages = false
|
||
|
#If this is true then the RFTools teleportation system cannot be used to travel in the same dimension
|
||
|
preventInterdimensionalTeleports = false
|
||
|
#Comma separated list of dimension ids that the teleportation system can't teleport from
|
||
|
blacklistedTeleportationSources = ""
|
||
|
#Comma separated list of dimension ids that the teleportation system can't teleport to
|
||
|
blacklistedTeleportationDestinations = ""
|
||
|
|